Description
MJK, Pressure Transmitter 3400, Range 030ft, 39ft Cable. Zener Intrinsically Safe Barrier, MTL7787. Nominal Measuring Range: 01 ft . 03 ft. 010 ft. 030 ft. 0100 ft. 0300 ft. 01000 ft. Measuring principle: Ceramic capacitive, relative pressure Sealed gate Min. programmable range: 0.9 ft. 0.9 ft. 03 ft. 09 ft. 030 ft. 090 ft. 0300 ft. Max. Programmable range: 03 ft. 03 ft. 010 ft. 030 ft. 0100 ft. 0300 ft 01000 ft. Max. overpressure: 75 psi 75 psi 100 psi 150 psi 275 psi 600 psi 600 psi
Temperature range: 5 °F to 105 °F
Temp. Deviation, zero point: Better than ± 0.01 % / °F
Temperature deviation, FS: Better than ± 0.005 % / °F
Linearity / Stability: Better than ± 0.5 % FS / ± 0.5 % FS
Measurement accuracy: Better than ± 0.1 % FS @ 50?85 °F
Better than ± 0.2 % FS @ full temperature range
Long time stability: Better than ± 0.1 % FS per year
Materials: Housing: PPS (Ryton),
Diaphragm: 99,9 % Al2O3
Packing: Viton®
Supply voltage: 10?30 V DC (1230 V DC for cable lengths above 315 ft.) Output signal: 2wire 420 mA (passive transmitter)
Cable: 2 × AWG 20 (pressure) + 5 x AWG 25 (data), shielded, PUR insulation
Cable length: 39 ft. 39 ft. 39 ft. 39 ft. 115 ft. 330 ft. 1030 ft.
Enclosure: NEMA 6P, withstands a static pressure equal to max.
Overpressure.
Safety Approvals: UL® Class I, II and II, Division 1 Hazardous (Classified)
Locations, UL 913. ATEX: II 2G EEx ia IIC T4…T6
Test Approvals: CE directive: 89/336/EEC, 2004/108/EC, 1999/EC
EN 613261, 61326?2?3, EN 55011, 6100042, 6100043, 6100044, 6100045,6100046, 6100048 EN 61000?6?4 2007029, EN 6100062 20050908,
The cable length may be extended by using the transmitter connection box (202922) and twisted shielded pair wire.
Reviews