Description
E&H Promass F 300, 8F3B40, DN40 1 1/2″”
Coriolis flowmeter
Inline version.
Application: Highest measurement
performance for liquids and gases under
varying, demanding process conditions.
Compact and robust dual-tube sensor.
Pressure-rated sensor housing.
Compact dual-compartment housing.
:: Premium accuracy, robustness and a
compact, easily accessible transmitter.
Order code description
GB Approval; Transmitter + Sensor: EAC; Z0/1, Z21,
Ex de, IIC/IIIC
E Power Supply: 100-230VAC
CA Output; Input 1: 4-20mA HART Ex-i passive
A Output; Input 2: W/o;
A Output; Input 3: W/o;
A Display; Operation: W/o; via communication
A Housing: Alu, coated
A Electrical Connection: Gland M20
SA Meas. Tube Mat., Wetted Parts Surface: Stainl.
steel, not polished
ABS Process Connection: Cl.300 RF, 1.4404/316/316L,
flange ASME B16.5
A Calibration Flow: 0.10% Mass
A1 Device Model: 1
AA >Operation Language Display: English
DE >>Customized Parameterization: Output 1, gas
JB >>Test, Certificate: Pressure test, internal
procedure, test report
JC >>Test, Certificate: Inspection certificate 3.1,
EN10204 (material certificate wetted parts+
sensor housing)
Details
Select medium Gas
Select gas type Air
Reference sound velocity 0.00000 m/s
Temperature coefficient
sound velocity
0.00000 (m/s)/K
Partial pipe detection Off
Flow damping 0.250 s
Low flow cut off 45.00000 kg/h
Curr. output 1 Mass flow
Current span 4…20 mA NAMUR
4 mA value 0.00000 kg/h
20 mA value 1,000.00000 kg/h
Failsafe mode current
output
Max.
Damping output 1 1.00000 s
Details
Select medium Gas
Select gas type Air
Reference sound velocity 0.00000 m/s
Temperature coefficient
sound velocity
0.00000 (m/s)/K
Partial pipe detection Off
Flow damping 0.250 s
Low flow cut off 45.00000 kg/h
Curr. output 1 Mass flow
Current span 4…20 mA NAMUR
4 mA value 0.00000 kg/h
20 mA value 1,000.00000 kg/h
Failsafe mode current
output
Max.
Damping output 1 1.00000 s




































Reviews
There are no reviews yet.