Description
Endress + Hauser Proline Promag W 300
electromagnetic flowmeter
Approval; Transmitter + Sensor:
AA
Non-hazardous area
Design:
E
Fixed flange
Power Supply:
I
100-230VAC/24VDC
Output; Input 1:
BA
4-20mA HART
Output; Input 2:
E
Pulse/freq./switch output
Output; Input 3:
A
W/o;
Display; Operation:
F
4-line illum.; touch control
Housing:
A
Alu, coated
Electrical Connection:
D
Thread NPT1/2
Liner:
H
Hard rubber
Process Connection:
A2S
Cl.300, stainl. steel, flange ASME B16.5
Electrodes:
0
1.4435/316L
Calibration Flow:
A
0.5%
Device Model:
A1
1
>Operation Language Display:
AA
English
>>Additional Approval:
LA
SIL
Details:
Curr. output 1: Volume flow
Current span: 4…20 mA US
4 mA value: 0 USgal/min
20 mA value: 600.00000 USgal/min
Failsafe mode current output: Max.
Damping output 1: 1.00000 s
Operating mode: Pulse
Assign pulse output: Volume flow
Pulse value (per pulse): 5.00000 USgal
Pulse width: 100.00000 ms
Failsafe mode pulse output: No pulses
Format display: 1 value, max. size
Value 1 display: Volume flow
Value 2 display: None
Value 3 display: None
Value 4 display: None
Display damping: 0 s
Totalizer 1: null
Unit: USgal
Operating mode totalizer: Net flow total
Failure mode: Stop
Totalizer 2: null
Unit: USgal
Operating mode totalizer: Net flow total
Failure mode: Stop
Totalizer 3: null
Unit: USgal
Operating mode totalizer: Net flow total
Failure mode: Stop.