Description
Endress+Hauser Promag P 10, 5PBB25, DN25 1″
AA Approval; Transmitter + Sensor: Non-hazardous area
E Design: Fixed flange
A Functionality: Standard transmitter
D Power Supply: 24VDC
B Output; Input: 4-20mA HART, Electromagnetic flowmeter
Inline version.
Dedicated to chemical and process
applications with corrosive liquids.
Wide variety of electrode materials.
Liner: PTFE, PFA.
App; display and touch screen optional.
Communication: HART or Modbus RS485.
:: Meter for basic process applications
with easy-to-use operation concept.
Order code description
AA Approval; Transmitter + Sensor: Non-hazardous area
E Design: Fixed flange
A Functionality: Standard transmitter
D Power Supply: 24VDC
B Output; Input: 4-20mA HART, pulse/freq./switch
K Display; Operation: LCD, 2.40″”; touch screen,
SmartBlue app
A Housing: Compact, alu, coated
0 Cable, Sensor Connection: Not used
A Electrical Connection: Gland M20
E Liner: PTFE 130oC
D5K Process Connection: PN40, carbon steel, flange
EN1092-1
0 Electrodes: 1.4435/316L
A Calibration Flow: 0.5%
A1 Device Model: 1
Details
Curr. output 1 Volume flow
Current span 4…20 mA NAMUR
4 mA value 0.00000 dm3/min
20 mA value 75.00000 dm3/min
Failsafe mode current
output
Max.
Damping output 1 1.00000 s
Value 1 display Volume flow
Value 2 display None
Value 3 display None
Value 4 display None
Display damping 1.00000 s
Totalizer 1
Unit dm3
Operating mode totalizer Net flow total
Failure mode Stop
Totalizer 2
Unit dm3
Operating mode totalizer Forward flow total
Failure mode Stop
Totalizer 3
Unit dm3
Operating mode totalizer Reverse flow total
Failure mode Stop
(Replacement for 10E25-8A0A1AA0A5AA).